PRODUCTS CATEGORY
HOT PRODUCT
Contact Us
- josephine@seeiyo.com
-
Wechat,Telegram,Line,
Whatsapp:+8618030983224 - Skype:1004611300@qq.com
ABB RTA Board PU516A 3BSE032402R1 Real Time Accelerator Module
Description
.Many products are not yet on the shelves please contact us for more products
.If there is any inconsistency between the product model and the picture on display, the model shall prevail. Contact us for the specific product picture, and we will arrange to take photos in the warehouse for confirmation
.We have 16 shared warehouses around the world, so please understand that it can sometimes take several hours to accurately return to you. Of course, we will respond to your concerns as soon as possible
Pu516a RTA Board
ABB RTA Board PU516A 3BSE032402R1 Real Time Accelerator Module.The analog output module provides an isolated current loop to output its signal level following the sensor. The output circuit is a passive current control element, and the loop voltage can be as high as 40V.
The recommended connections are as follows:
Analog output + 0V + 24V (10V to 40V)
Relay / field interface card
05701-A-0326
05701-A-0327
05701-A-0328
05701-A-0329
The programmable thinking mode controller isolates the analog output connection, and the power source is from:
PLC 3132 single channel control card
05701-A-03014-20mA
05701-A-0302
The catalytic converter is equipped with analog output module 05701-a-0285. The analog output can be configured as 0-20mA or 4-20mA output mode. Check the configuration table provided with the system to determine the factory configured operating mode.
Operating mode:
You can easily reconfigure ports using a computer connected to a project. For more information, please contact Zellweger analytics or your local agent.
The analog output can be connected to a voltage input device (e.g. A. chart recorder), including and connecting the device input in parallel with a resistor. That is, use a 100 ohm resistor and select an input range of 2V on the chart recorder relay / field interface card remote input connection note that connecting a voltage exceeding 32V to the remote input may cause permanent damage to the single channel control card.
There are two remote inputs, reset and inhibit, which can be configured as active high or active low operation mode. Check the configuration table provided with the system to determine the operation mode configured by the factory. The operating mode can be reconfigured to easily use the computer connected to the engineering port. Contact Zellweger analytics or your local agent for more information.
The switching level of the remote input pin (when enabled) is about + 2V relative to 0V of the DC system. The input requires a drive current less than 5mA, which is internally pulled down to the system 0V regardless of the configuration.
The active high remote input may not be connected or may be connected to + 24V through normally open contacts. The remote input will run whenever the contact is closed.
The active low level remote input can be normally connected to the + 24V closed contact. The remote input will work on whenever contacted. Do not leave the low level input disconnected.
Main product :
ABB: Industrial robot spare parts DSQC series, Bailey INFI 90, IGCT, etc., for example: 5SHY6545L0001 AC10272001R0101 5SXE10-0181,5SHY3545L0009,5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512 a10-15000 3BHE040375R1023, PPD113, PP836A, PP865A, PP877, PP881, PP885,etc.,
GE: spare parts such as modules, cards, and drivers. For example: VMIVME-7807, VMIVME-7750, WES532-111, UR6UH, SR469-P5-HI-A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A , IC698CPE010,IS200SRTDH2ACB,etc.,
Bently Nevada: 3500/3300/1900 system, Proximitor probe, etc.,for example: 3500/22M,3500/32, 3500/15, 3500/20,3500/42M,1900/27,etc.,
Invensys Foxboro: I/A series of systems, FBM sequence control, ladder logic control, incident recall processing, DAC, input/output signal processing, data communication and processing, such as FCP270 and FCP280,P0904HA,E69F-TI2-S,FBM230/P0926GU,FEM100/P0973CA,etc.,
Invensys Triconex: power module,CPU Module,communication module,Input output module,such as 3008,3009,3721,4351B,3805E,8312,3511,4355X,etc.,
Woodward: SPC position controller, PEAK150 digital controller, such as 8521-0312 UG-10D,9907-149, 9907-162, 9907-164, 9907-167, TG-13 (8516-038), 8440-1713/D,5466-258, 8200-226,etc.,
Westinghouse/Emerson: OVATION system, WDPF system, MAX1000 system spare parts, such as 1C31129G03, 5X00063G01, 5X00063G01,1C31181G01,SE3007, VE3008, etc
Rockwell Allen-Bradley:Logix 1756,1794,2711touch screen such as 2711-B6C20,etc.,
Rockwell ICS TRIPLEX:T8151B,T8311 ,T8403 ,T9431, T8480C,etc.,
Rockwell Reliance:PLC-MODULE,WR-D4007,0-57406-E,Y-3023-2-H00AA,etc.,
Schneider Modicon: Quantum 140 series processor, control card, power module,
such as 140CPU65160, 140CPU67160, 140CPU43412,140CPU67060,140DDI35300,140ACO13000,140CRA93100,140CPU11303,140ACO13000,etc.,
Hima: Security modules, such as F8650E, F8652X, F8627X, F8628X, F3236, F6217,F6214, Z7138, F8651X, F8650X,etc.,
Honeywell: all DCS cards, modules, CPUS, such as: CC-MCAR01, CC-PAIH01, CC-PAIH02, CC-PAIH51, CC-PAIX02, CC-PAON01, CC-PCF901, TC-CCR014, TC-PPD011,CC-PCNT02,etc.,
Motorola: MVME162, MVME167, MVME172, MVME177 series, such as MVME5100, MVME5500-0163, VME172PA-652SE,VME162PA-344SE-2G,etc.,
Xycom: I/O, VME board and processor, for example, XVME-530, XVME-674, XVME-957, XVME-976,etc.,
Kollmorgen:Servo drive and motor,such as S72402-NANANA,S62001-550,S20330-SRS,CB06551/PRD-B040SSIB-63,etc.,
Bosch/Rexroth/Indramat: I/O module, PLC controller, driver module,MSK060C-0600-NN-S1-UP1-NNNN,VT2000-52/R900033828,MHD041B-144-PG1-UN,etc.,
Mailbox:josephine@seeiyo.com | ABB PU516A 3BSE032402R1 |